Heat-seal Element Replacement Measurements: Components, Compatibility and Maintenance

13 October 2026 · Heat Seal Components
Heat-seal Element Replacement Measurements: Components, Compatibility and Maintenance

A replacement heat-seal element is only as useful as the information supplied with it. A single end-to-end length rarely explains how the part sits in the sealing assembly, where the heated section starts, or how the terminals face the machine. A better record combines the application, fitted form, active section, overall dimensions, terminals and supporting parts.
This guide sets out a practical record for a removed element or a part that is still fitted. It is intended for engineers and maintenance teams working with impulse sealers, vacuum packers, VFFS and flow-wrap equipment. The final dimensions must always be checked against the machine information and the part itself.

Why replacement measurements need more than one length

Start with the machine and sealing application

Begin with the machine make and model, the sealing method and the position of the element in the assembly. Record whether the part is used in an impulse sealer, vacuum packing machine, VFFS line or flow-wrap equipment. Note whether it is an upper or lower sealing part and whether it sits in a jaw, bar or another carrier.
This context helps separate a genuinely compatible replacement from a part that only appears similar. Heat Seal Components’ heat-seal element service explains that elements can be made to dimensions, profiles and terminal arrangements. Where the specification is uncertain, the old element, a drawing or a clear sketch can help the supplier assess the request.

Separate overall length from active heated length

Overall length runs from the outside of one terminal or end feature to the corresponding point at the other end. Active heated length is the section that performs the seal. They are not interchangeable. A part can have the right overall length but the wrong heated zone, leaving the seal in the wrong position.
Record the two measurements separately and mark the reference edges used. Also record any transitions, necked sections or unheated end areas. The diagram below shows the order in which the main inputs can be recorded.
Technical diagram showing the order for recording machine application, fitted form, active length, overall length and terminal layout.

Capture profile, width, thickness and terminations

Record the element profile as it is fitted, including its width, thickness, bends and terminal shape. If the part is a wire, ribbon or flat element, say so in the record rather than relying on a photograph to communicate the section.
Measure terminal centre spacing, hole or fixing details and the direction in which each terminal turns. Photograph the part from above and from the mounting side. If a terminal has been bent, cracked or distorted, note that condition instead of treating the damaged shape as the intended design.

Build a measurement record before ordering

Record the fitted form and cross-section

Do not flatten or straighten a shaped element just to make it easier to measure. Record the form in the condition in which it locates in the assembly, then take separate measurements for straight lengths, bends and offsets. A simple sketch with arrows is often clearer than a list of disconnected numbers.
If the element sits beneath a cover or in a support, identify which surface controls its position. The part that looks longest may be the cover or carrier rather than the heating element. Heat Seal Components’ custom impulse elements service is a useful starting point when the required profile or construction is unclear.

Document terminal layout and mounting orientation

The terminal arrangement is part of compatibility. Record which face is presented to the machine, the direction of any upstand, the spacing between fixing points and whether the terminals are parallel, opposed or offset. Include a photo with a simple arrow showing the mounting side.
Detached heat-seal element terminals positioned to record their layout and mounting orientation. When a part has two visually similar ends, label them in the record. This avoids turning the element around during installation and then trying to correct the fit by bending the terminals. If the assembly uses a sealing jaw or bar, cross-check the carrier and fixing pattern against the relevant sealing jaws and bars service information.

Note the support and cover separately

The PTFE cover, support bar and heating element may have different lengths and widths. Record each one separately, but identify the heating element as the part to be replaced. A cover can overhang the active section, while a support can extend beyond both ends.
Diagram distinguishing the heat-seal element from its cover and support parts before measurement. The same principle applies when a strip has been replaced more than once. A worn cover or carrier may have been trimmed, stretched or moved during maintenance. Treat those changes as maintenance history, not as proof of the replacement element’s intended dimensions. If tape is part of the assembly, describe its position and condition separately from the element. Heat Seal Components’ PTFE heat-seal tape service covers that component category without confusing it with the raw element.

Measure a removed element safely

Isolate, cool and photograph first

Follow the machine manufacturer’s procedure before removing anything. HSE maintenance guidance highlights safe isolation, release of stored energy and cooling of hot components. Use lock-off and verification procedures required by the site, and make sure the work is carried out by a competent person.
Photograph the installed arrangement before disturbing the part. Then photograph the removed element, terminals and support surfaces before cleaning or straightening it. Keep the first images with the measurement record so later measurements can be traced to the original condition.

Keep the old element unstretched

Lay the removed part on a clean surface without pulling it tight. If it is distorted, record both the relaxed condition and the way it was located in the machine. Do not infer the original length from a broken or stretched element without checking the assembly and any available drawing.

Use one reference edge

Measure from defined edges and write down whether a value is taken from the element, terminal, cover or support. Keep the unit consistent, preferably millimetres for component dimensions. A short sketch showing datum edges, active-zone marks and terminal centres is easier to audit than a photograph alone.
HSE inspection guidance recommends a risk-based approach and recording inspection results. That same discipline is useful here: date the record, identify the machine, name the person taking the measurements and note any uncertainty.

Use electrical data as a cross-check

Resistance confirms part of the specification

If it is safe and appropriate to do so, record the resistance of the removed element with the test conditions. Resistance can support an identification, but it does not replace dimensional and mechanical information. A measurement taken at an unstated temperature or through a poor connection can mislead the replacement decision.
Kanthal’s standard tolerance guidance separates size tolerances from resistance tolerances and uses a 20°C reference for resistance values. Use that as a reminder to record test conditions, not as a universal tolerance for an element made for a particular sealing machine.

Cross-check with machine-side information

Where available, record the machine voltage, power setting or controller information from the machine documentation. Kanthal’s design calculations show why electrical and physical inputs need to be considered together. Do not substitute generic calculations for the machine maker’s information or a confirmed supplier specification.

Common measurement mistakes to avoid

  • Sending only one overall length with no profile or terminal detail.
  • Measuring the PTFE cover or support bar instead of the heating element.
  • Straightening a formed part and losing its installed shape.
  • Omitting which face or terminal side is presented to the machine.
  • Treating a damaged terminal as the intended terminal layout.
  • Recording resistance without the test conditions or connection points.
  • Assuming a visually similar part is compatible without checking the machine application.

What to send with a replacement enquiry

Assemble one record containing:

  • machine make, model and application;
  • a labelled photograph of the installed assembly;
  • overall length and active heated length;
  • profile, width, thickness, bends and terminal details;
  • terminal orientation, fixing centres and mounting side;
  • separate measurements for the element, cover and support;
  • any resistance reading and its test conditions;
  • a sketch or the removed element where the shape is difficult to describe.

If the item is part of a sealing jaw, bar or vacuum packing assembly, include that context in the enquiry. Heat Seal Components can review the component information through its contact page. Clear measurements do not need to be perfect to be useful, but they do need to identify what was measured and how the part is meant to fit.