Testing a failed impulse-sealer element is not just a case of checking whether a meter beeps. The element may be open, poorly connected, distorted, shorted to a support or affected by a damaged cover. The test must also be done safely and interpreted alongside the fitted component.
This guide is for UK packaging engineers, maintenance technicians, production managers and procurement teams checking an impulse or bench sealer. It explains what to inspect, how to approach a dead continuity or resistance check, and what evidence to send when a replacement heat-seal element may be needed.
Start with a safe visual inspection

Isolate the sealer before opening it
Maintenance work should be planned and carried out by a competent person. HSE guidance says to stop moving plant, isolate electrical supplies, lock off where accidental reconnection is possible, release stored energy and allow hot components to cool before maintenance. Read the machine maker’s instructions and follow the site’s safe system of work.
For electrical testing, the apparatus should be dead wherever possible. HSE guidance on electrical testing explains that testing work must be arranged to control the risk of shock, burns and other danger. Do not remove a cover or touch an element because the timer has finished or an emergency stop has been pressed.
Inspect the whole sealing assembly
Record the condition before removing the failed part. Look for:
- a visible break, notch or thin section in the element;
- loose, darkened or overheated terminals;
- a displaced or damaged PTFE cover or heat-seal tape;
- a cut, crushed or uneven support surface;
- an element that is twisted, slack, stretched or out of its intended path.
An element can be electrically continuous and still produce a poor seal if it is not supported correctly or if the cover and contact surfaces are damaged. Take photographs of the complete sealing bar, both ends and the component path. Keep the original part if it can be removed safely.
The heat-seal elements service page is a useful scope reference for replacement elements. It does not replace a record of the part actually fitted to the machine.
Check continuity and cold resistance

Use a dead test with suitable equipment
After safe isolation, confirm that the test equipment and leads are suitable and in good condition. HSE GS38 says that continuity testing can often be carried out safely with the apparatus dead, using a self-contained low-voltage DC source and indicator after isolation procedures have been adopted. Its guidance on electrical test equipment for low-voltage systems also covers protected leads, correct meter settings and competent use.
Disconnect the element from the circuit before measuring it. Testing through a controller, transformer, switch, parallel path or attached wiring can give a reading that belongs to the wider circuit rather than the element. Keep the probes on the intended terminals and avoid damaging the element while making contact.
Interpret the result with care
A stable continuity indication or a measurable cold resistance shows that there is an electrical path between the test points. It does not prove that the element is the correct size, profile, material, active length or power specification.
An open-circuit indication suggests a break in the element or its terminal connection, but it should be checked against the physical inspection. A high, unstable or changing reading may point to poor probe contact, a loose terminal, contamination or a damaged connection. Clean and secure the test points only within the machine maker’s instructions and the site’s safe system of work.
Do not use a generic resistance value as a pass or fail limit. The expected cold resistance depends on the element’s material, cross-section, length, connection arrangement and machine design. Kanthal’s resistance-wire guidance shows why wire form, alloy, dimensions and operating conditions belong together in a heating-element specification.
Record the evidence, not only the number
Write down the test state and the component details with the result:
- machine make, model and sealing station;
- impulse or bench-sealer application;
- element form, such as round wire, flat ribbon or a formed part;
- wire diameter or ribbon width and thickness;
- active heated length and overall length;
- terminal style, fixing centres and connection route;
- cover, insulation, support and tensioning condition;
- the meter function and the reading observed at the element terminals.
If the original data is unknown, mark it as unknown. A reading without clear test points, temperature state and component identity is weak evidence for a replacement.
Separate the element from the machine-side fault

An open element is only one possible cause
If the element is open at its own terminals and the break is visible, the replacement investigation can focus on the element and the conditions that may have damaged it. If the element tests continuously, inspect the terminals, connection hardware, cover, support, control circuit and machine operating sequence before ordering a new part.
An impulse-sealer manual may list a broken heating element alongside other causes of no sealing, such as a disconnected plug, damaged cord or transformer fault. That is a useful reminder to trace the fault rather than replacing a component on the basis of one symptom. Use the machine-specific manual for the actual test and replacement procedure.
Look for conditions that could damage the replacement
Compare the failed component with the bar and cover around it. Check whether the element was rubbing, folded, clamped unevenly or left without the intended insulation or cover. Record contamination, scorching, loose fixings and changes made before the failure.
Do not assume a new wire or ribbon will correct a damaged support or unstable terminal. The sealing jaws and bars service page is relevant when the wider mechanical assembly needs to be identified as part of the component review.
Know when to request a custom element review
An unusual terminal pattern, formed path, stepped end, non-standard active length or incomplete drawing can make a standard replacement unsafe to assume. The custom impulse heat-seal elements service is the relevant route for a non-standard impulse component enquiry.
Send the available evidence in one pack. Include the removed element where safe, marked-up photographs, a dimensioned sketch, both terminal views, the sealing-bar details, machine make and model, and any documented voltage, power or resistance information. Ask for the profile, active length, terminals and electrical details to be confirmed before ordering.
Match the replacement to the application
Impulse and bench sealers
For a straight bar element, confirm the seal length, active heated length, ribbon or wire dimensions, end form and fixing position. A part with the same nominal seal length may still differ in profile, terminal arrangement or cover requirements.
Vacuum packers, VFFS and flow-wrap equipment
If the part is used in a wider packaging assembly, identify the station and the element path. Vacuum packers may use bar-mounted elements, while VFFS and flow-wrap equipment can use formed or paired sealing components. The custom impulse elements page can provide application context, but the installed part and machine documentation remain the evidence for compatibility.
Procurement check before ordering
Before requesting a replacement quote, confirm that the evidence pack contains the original component or clear photographs, measured dimensions in millimetres, terminal details, support and cover information, machine and station details, and the result of any dead electrical check. Separate measured facts from assumptions so an uncertain dimension is not mistaken for a confirmed specification.